Construction Engineering Verified Calculator

Energy Load Audit Calculator

Convert appliance watts and daily running hours into a daily energy demand in watt-hours and kilowatt-hours.

Add this calculator to the Construction Workflow

Geometry-based calculation.A simple energy ledger: six appliance rows of watts and daily hours. It does not include seasonal variation, duty cycles or standby loads you do not list.

Equipment load schedule and daily energy total Six equipment rows whose bar lengths are rated power in watts, each annotated with its daily energy and share of the total, summing to the daily energy demand that sizes an array, battery or inverter. Load 1 W Wh/day Load 2 W Wh/day Load 3 W Wh/day Load 4 W Wh/day Load 5 W Wh/day Load 6 W Wh/day DAILY ENERGY kWh/day CONNECTED W ratings summed — assumes all run at once
  • Rated power (W) — bar length
  • Equipment row
  • Accumulated energy (Wh/day)
Six equipment rows whose bar lengths are rated power in watts, each annotated with its daily energy and share of the total, summing to the daily energy demand that sizes an array, battery or inverter. Schematic only — not to scale and not a construction drawing. Bar length is rated power; it is not energy and the bars do not add up to the total. The model holds six static rows with no duty cycle, no seasonal variation and no time-of-use data. Connected power assumes every listed load runs simultaneously, which is an assumption about your installation, not a measured value.

Workspace

Continue where you left off

Saved calculations in this browser can be reopened with their inputs intact.

Open Workspace

What this calculator does

Solar arrays are sized from energy, not from power. This calculator turns a list of appliances and how long each runs per day into the daily energy demand in watt-hours and kilowatt-hours, which is the input every other sizing tool in this group needs.

How to use it

  1. Fill in watts and daily hours for each of the six rows, leaving unused rows blank.
  2. Refrigerators and freezers cycle, so estimate their compressor running hours rather than 24.
  3. The total is a daily average; multiply by 30 for a monthly estimate.
  4. Check the result against your utility bills, which are the best reality check available.

Governing formula

Governing Formula
E_day = Σ (W_i × h_i)

Where:

  • W_i = Rated power of appliance i [W]
  • h_i = Running hours of appliance i per day [h]

Derived Equations:

Approximate monthly energy: E_month = E_day × 30

Worked example — Lighting, refrigeration, washing and a laptop

The figures below were produced by running this page's own engine with the example inputs (Row 1 — watts (W), Row 1 — hours per day (h), Row 2 — watts (W), Row 2 — hours per day (h), Row 3 — watts (W), Row 3 — hours per day (h), Row 4 — watts (W), Row 4 — hours per day (h), Row 5 — watts (W), Row 5 — hours per day (h), Row 6 — watts (W), Row 6 — hours per day (h)). If the calculator returns something different for the same numbers, that is a bug, not a rounding difference.

Expected results for the worked example
Daily energy demand7440 Wh
Daily energy demand7.44 kWh
Average hours of use4.38 h
Next stepDaily energy 7.44 kWh (7440 Wh). Use this as the input to the array, battery, inverter and charge-controller sizers on this page group.
  1. Lighting contributes 4,000 Wh and the refrigerator 1,200 Wh.
  2. The washing machine and laptop add 2,000 Wh and 240 Wh.
  3. The daily total is around 7.4 kWh, which is the input to the array sizer.

Assumptions & limitations

Engineering calculation. A simple energy ledger: six appliance rows of watts and daily hours. It does not include seasonal variation, duty cycles or standby loads you do not list.

  • Duty cycles, variable compressor loads and standby power are not modelled — real consumption is often 10–20 % higher.
  • No seasonal or weekday/weekend variation, which matters for battery sizing.
  • Nameplate watts overstate real power for appliances with power factor correction.
  • The schedule is fixed at six load rows by the calculation model. A larger audit must be split across separate runs, and totals from separate runs are not added together for you.
  • Connected power is the sum of the listed ratings. It assumes every load runs at once, which is rarely true, and it is not a measured peak demand.

This tool supports professional engineering work; it does not replace a sealed design. Confirm every result against the applicable standard and a licensed engineer before it is built.

References & standards

  • NREL PVWatts — system loss assumptions used for the derating default.
  • Australian Government — off-grid solar sizing guidance.
Engineering Disclaimer & Verification Notice

This calculator provides preliminary engineering estimates for informational and planning purposes. Actual reverse osmosis / engineering system performance depends on site conditions, feed-water chemistry, membrane characteristics, operating pressure, temperature, recovery limits, fouling/scaling potential, and system design. Verify results using project-specific data, manufacturer projections, and applicable engineering standards before final design or operation.