Enter the feedwater analysis once. The surface derives the parameters that do not need a model —
hardness, cation–anion charge balance, TDS by summation, ionic strength — and, when the chemistry
is complete, reuses the platform’s saturation-indices engine (LSI/RSI). The second panel maps
observed water-quality drivers to candidate unit operations already built here; it is a
starting point for verification, never a thresholded diagnosis.
Feedwater analysis
Optional fields only narrow the picture. Nothing is inferred from absent values — a field left blank
simply skips the derivation it would enable.
Treatment selection ladder
Each driver is matched to the unit-operation surfaces already running on the platform, with the
engineering step that must be verified (jar test, pilot, membrane projection, governing standard).
1
Elevated TDS / salinity on a brackish or seawater feed
Brackish and seawater desalting is an RO application space. Confirm feed characterisation, recovery target and concentrate disposal route with the owning authority and a membrane projection.
2
Suspended solids / particulate fouling risk ahead of a membrane train
A scaling indication flags the need to manage the concentrate thermodynamics — antiscalant, acid or softening route selected against the actual salt system, not a rule-of-thumb.
NF and IX are application-specific separations; confirm the target constituent and the resin/membrane specification with laboratory or manufacturer data.
Develop the plant-wide water and salt balance first, then iterate stage recovery and make-up against the verified feedwater analysis.
Method and references
Hardness = 2.497·Ca + 4.118·Mg (mg/L as CaCO₃) — the standard calcium/magnesium conversion factors.
Charge balance uses equivalent weights (Ca 20.04, Mg 12.15, Na 22.99, K 39.10 mg/meq; HCO₃ 61.02, CO₃ 30.00, Cl 35.45, SO₄ 48.04 mg/meq).
Ionic strength and LSI/RSI reuse the platform’s scaling-risk.ts / saturationIndices.ts engines — no constants are duplicated.
Cation–anion balance within ±5 % is a widely used acceptability guideline (e.g., Standard Methods practice for validating analyses); treat deviation as a trigger to re-check the analysis, not a quality verdict.
The treatment ladder points to genuine platform surfaces and carries no numeric cut-offs.
Engineering Disclaimer & Verification Notice
This surface derives standard parameters and cross-references treatment surfaces; it does not provide a diagnosis, a treatment guarantee, or a compliance verdict. Confirm the feedwater analysis with the laboratory, and verify any unit-operation choice with jar/pilot work and the jurisdiction's governing standard.