Water • Ro Microsoft Excel (.xlsx)

RO Recovery & Concentrate Flow

Compute permeate and concentrate flows from feed flow and recovery percentage.

What this workbook is

A real, downloadable Microsoft Excel workbook — not a rendered demo. Every sheet is built around a single engineering method: inputs in one place, calculated results and a PASS / WARN / FAIL check sheet, with the method, sources and assumptions recorded next to the numbers. Open it in Excel, Sheets or LibreOffice, change the inputs, and the workbook recalculates.

  • Light cells are user-entered inputs on the Inputs sheet.
  • Dark cells are calculated automatically and are not editable.
  • The method and sources for every calculation are listed below and inside the workbook.

What you enter

  • Feed flow (mآ³/h)
  • Recovery (%)

What it calculates

  • Permeate flow
  • Concentrate flow
  • Concentration factor

Method

Qp = Qf أ— Y/100; Qc = Qf − Qp; CF = 1/(1−Y)

Sources

  • [1] Dupont Water Solutions RO system design (method-level)

Inside the workbook

CoverTitle, scope and revision block
SummaryCore inputs and headline results
InputsYour project values (light cells)
CalculationsStep-by-step working sheet (dark cells)
OutputsReadback of results for reporting
ChecksPASS / WARN / FAIL against stated limits
ReferenceSources for each calculation
Notes & AssumptionsScope, exclusions and stated limits