A 15 kW motor for a 120 m3/h pump: hydraulic or input power?

  • Spot the Error
  • Mechanical & Fluids
  • intermediate
Competency Quantitative reasoning primary Systems and balances supporting

What you should take away: Separate hydraulic power, shaft power and motor input power, and recognise that motor sizing must include both efficiencies.

The situation

What is happening

A pump delivers 120 m3/h against a total dynamic head of 42.9 m. The pump efficiency is 75 % and the motor efficiency is 92 %. The reviewer specifies a 15 kW motor because the hydraulic power is about 14 kW. What calculated motor input power does the review establish before selecting a standard motor?

Given

Scenario values with units
QuantityValueUnitNote
Flow rate 120 m3/h Design flow.
Total dynamic head 42.9 m Static, friction, minor and residual head.
Pump efficiency 75 % Hydraulic-to-shaft efficiency.
Motor efficiency 92 % Shaft-to-electrical input efficiency.
Reviewer selection 15 kW Based on hydraulic power only.

Assumptions this challenge makes

  • The stated total dynamic head already includes static, friction, minor and residual pressure head.
  • Pump and motor efficiencies are operating-point values, not catalogue maxima.
  • The answer is the calculated motor input, not the next standard motor rating.

Your call

Your answer

Enter the calculated motor input before choosing a standard motor size.

What this challenge does not establish

  • The efficiencies are single operating-point inputs; real pump and motor efficiency vary with load.
  • The calculation does not model viscosity, solids, suction conditions or motor service factor.
  • Motor starting, voltage dip, altitude derating and duty cycle are separate checks.
  • The result is a calculated input, not a guarantee that a particular motor will deliver the duty.