Review this RO energy calculation: the credit is missing

  • Spot the Error
  • Water Treatment & Desalination
  • intermediate

What you should take away: Recognise that an energy figure issued without the ERD credit is a gross figure, and distinguish a design bound from a predicted operating value.

The situation

A design review receives a specific-energy figure for a seawater RO plant that has an isobaric energy recovery device fitted on the brine stream. The reviewer must decide whether the issued figure can be relied on. Every figure below was produced by the same energy engine used by the RO energy calculator.

Given

Scenario values with units
QuantityValueUnitNote
Feed flow 100 m³/h Feed to the reverse-osmosis stage.
System recovery 45 % Permeate as a fraction of feed. Sets the brine flow.
Feed pressure 55 bar Membrane inlet pressure.
Pump efficiency 85 % Assumed pump efficiency.
ERD efficiency 95 % Is the energy recovery device fitted, and how efficient?

Constraints

  • Membrane elements are supplied whole. A fraction of an element cannot be ordered.
  • Pressure vessels are loaded with a whole number of elements — 6 per vessel here.
  • Every vessel in the array is filled to the same element count.

Your answer

Which finding is the defensible review conclusion for the issued figure?

What this challenge does not establish

  • The ERD credit is an upper bound: the engine assumes the brine expands from full feed pressure to atmospheric, so a real pressure exchanger recovers slightly less.
  • Feed pressure is taken as given. Concentrate-side pressure and the pressure drop across the ERD are not modelled.
  • This assesses the ENERGY figure only. Whether 55 bar is itself correct for this recovery is a separate osmotic-balance question.
  • No allowance is made for parasitic ERD power, pump efficiency variation with load, or part-load operation.