Choosing pretreatment so the membranes survive
Matching filtration and dosing decisions to the fouling and scaling risk of the raw water.
The engineering question
Membranes are fouling before their warranty is used up. What pretreatment does this water actually need?
Worked example
The figures below were produced by running the RO Antiscalant & Chemical Dosing Calculator with the same inputs .
These figures are worked by the published method rather than executed at build time, because this tool is a self-contained page calculator without a programmatic engine.
- Water analysis establishes which scalants are actually at risk, which is what decides the pretreatment.
- Antiscalant dose is expressed as ppm by mass of feed, so it follows from flow and concentration.
- Filtration and cartridge ratings then follow the fouling risk rather than the scaling risk.
- The choice itself remains judgement — the tools quantify the consequences, not the decision.
Sanity check
Dose in kg/day should follow flow × ppm ÷ 1000. A figure an order of magnitude out usually means the dose was entered as mg/L and treated as a percentage.
Tools for this problem
These are the EngiMetric calculators that compute the numbers in this topic. Each one shows its formula, its units and its limits rather than returning a bare result.
- Water Analysis & Treatment Selection Enter a feedwater analysis once: derive hardness, cation–anion charge balance, TDS by summation, ionic strength and saturation indices (LSI/RSI), then compare water-quality drivers against the treatment surfaces already built on the platform — a qualitative start, not a diagnosis.
- RO Scaling Risk & Pretreatment Analysis Screen CaCO3 scaling risk in RO feed and concentrate using the Langelier Saturation Index (ASTM D3739) and the Stiff & Davis Stability Index (S&DSI) for high-TDS and seawater feeds.
- RO Antiscalant & Chemical Dosing Calculator Calculate antiscalant (or chemical) dosing rate and 100% active-equivalent flow from dose concentration and product strength.
Engineering review required
This topic supports professional engineering work; it does not replace a sealed design. The result depends on site data, the governing standard and engineering judgement, and should be confirmed by a competent engineer before it is built.
References & standards
- DOWEX — pretreatment and membrane fouling
- Hydranautics — system design guidelines
Related problems
Choosing an RO recovery rate without scaling the membrane
How recovery drives concentrate quality, and why pushing it higher trades water for scaling risk.
What salt rejection means for permeate quality
Relating feed concentration, rejection percentage and permeate salinity, and reading the recovery calculator correctly.
Also: Chemical & Process