Storm Drain Sizing Calculator

Select the smallest standard storm drain pipe that passes the design flow and check the self-cleansing velocity.

Add this calculator to the Construction Workflow

Geometry-based calculation.Selects the smallest standard pipe that passes the design flow running full, and reports whether the self-cleansing velocity is achieved.

Workspace

Continue where you left off

Saved calculations in this browser can be reopened with their inputs intact.

Open Workspace

What this calculator does

Take the peak runoff your catchment produces, then find the pipe that carries it. This calculator does exactly that with the Manning equation, and additionally checks the velocity against the self-cleansing minimum — because a pipe that is too large runs slow and silts up permanently.

How to use it

  1. Enter the peak flow, which should come from the Rational Method or a hydraulic model rather than an average.
  2. Enter the available gradient; 0.5–1 % is normal for a site storm sewer.
  3. Enter the Manning roughness and the minimum self-cleansing velocity, 0.75 m/s being the usual rule of thumb.
  4. A "does not self-clean" verdict usually means the pipe is oversized for the slope — split the run rather than accepting a flat oversized pipe.

Governing formula

Governing Formula
Q = (1/n)·A·R^(2/3)·S^(1/2)

Where:

  • n = Manning's roughness coefficient [–]
  • S = Gradient [m/m]

Derived Equations:

Mean velocity when running full: v = (1/n)·R^(2/3)·S^(1/2)

Worked example — 0.5 m³/s at a 1:200 gradient

The figures below were produced by running this page's own engine with the example inputs (Design (peak) flow (m³/s), Gradient (m/m) (m/m), Manning's n (–), Minimum self-cleansing velocity (m/s)). If the calculator returns something different for the same numbers, that is a bug, not a rounding difference.

Expected results for the worked example
Required pipe size675 mm
Capacity at that size0.59 m³/s
Velocity when full1.66 m/s
Self-cleansing velocity met1
Assessment675 mm pipe at the selected slope runs full at 0.59 m³/s (1.7 m/s). Self-cleansing velocity met.
  1. A 450 mm pipe at this gradient cannot pass the flow, so the search moves up the standard sizes.
  2. The chosen barrel carries the design flow at a velocity above the self-cleansing minimum.
  3. Check the inlet capacity of the gully or catch pit, which often governs before the pipe does.

Assumptions & limitations

Engineering calculation. Selects the smallest standard pipe that passes the design flow running full, and reports whether the self-cleansing velocity is achieved.

  • Assumes the pipe runs full and at uniform flow; partial-flow conditions and backwater effects are not modelled.
  • No capacity reduction for inlets, gullies or manholes.
  • The self-cleansing velocity criterion is empirical — very large flows can be slower and still acceptable.

This tool supports professional engineering work; it does not replace a sealed design. Confirm every result against the applicable standard and a licensed engineer before it is built.

References & standards

  • BS EN 752-4 — underground drainage and piping systems, requirements and construction.
  • Local stormwater management manual — minimum velocity criteria.
  • Chow, Open-Channel Hydraulics.
Engineering Disclaimer & Verification Notice

This calculator provides preliminary engineering estimates for informational and planning purposes. Actual reverse osmosis / engineering system performance depends on site conditions, feed-water chemistry, membrane characteristics, operating pressure, temperature, recovery limits, fouling/scaling potential, and system design. Verify results using project-specific data, manufacturer projections, and applicable engineering standards before final design or operation.