EngiMetric Arena / Diagnose the Failure

Diagnose the RO train that lost output despite more pressure

  • Diagnose the Failure
  • Water & Desalination
  • advanced
Competency Fault diagnosis primary Systems and balances supporting Evidence interpretation supporting

What you should take away: Read normalized RO performance together with pressure drop, and separate fouling from a change in feed salinity or a sensor fault.

The situation

What is happening

An RO train is compared with its commissioning baseline. The operator has raised feed pressure from 55 to 58 bar, but normalized permeate flow is 17 % below baseline and feed-to-concentrate pressure drop has risen from 1.0 to 1.6 bar. Salt passage has increased slightly. Choose the diagnosis the normalized record supports.

Given

Scenario values with units
QuantityValueUnitNote
Baseline feed pressure 55 bar Commissioning record.
Current feed pressure 58 bar Raised by the operator.
Baseline pressure drop 1.0 bar Feed to concentrate.
Current pressure drop 1.6 bar Same train, current record.
Normalized flow change -17.1 % Corrected to reference temperature and baseline net driving pressure.

Assumptions this challenge makes

  • Feed TDS and temperature are unchanged between baseline and current records.
  • The membrane area is unchanged and the same train is being compared.
  • Normalization follows the analyzer’s ASTM D4516-style reference conditions.

Your call

Your answer

Which diagnosis is best supported by the normalized record?

What this challenge does not establish

  • The analyzer normalizes with a fixed temperature-correction approximation; the membrane maker’s own factor supersedes it when available.
  • A single baseline and current record cannot distinguish fouling from scaling, plugging or mechanical damage without inspection and water analysis.
  • Instrument bias is not detected by the model; field verification is required.
  • The model does not predict cleaning effectiveness or membrane remaining life.