EngiMetric Arena / Diagnose the Failure

Diagnose the gravelly noise at the pump suction

  • Diagnose the Failure
  • Mechanical & Fluids
  • intermediate
Competency Fault diagnosis primary Quantitative reasoning supporting Constraints and trade-offs supporting

What you should take away: Compute available NPSH from the suction layout and distinguish cavitation from air ingress or mechanical wear.

The situation

What is happening

A pump draws 40 degC water from a sump 3.5 m below the impeller. Suction-pipe friction at the duty flow is 3.0 m and the pump requires 4.0 m NPSH. At high flow the pump emits a gravelly noise, discharge pressure fluctuates and vibration rises. Choose the diagnosis the numbers support.

Given

Scenario values with units
QuantityValueUnitNote
Water temperature 40 degC Sets the vapour pressure.
Suction lift 3.5 m Sump level below the impeller.
Suction friction 3.0 m At the duty flow.
NPSH required 4.0 m From the pump curve at the duty flow.
Atmospheric pressure 101.3 kPa Site atmospheric pressure.

Assumptions this challenge makes

  • The suction lift and friction are stated at the duty flow where the noise occurs.
  • The fluid is water at 40 degC with a density of 1000 kg/m3.
  • NPSH required is taken from the pump curve, not estimated.

Your call

Your answer

Which diagnosis is best supported by the stated conditions?

What this challenge does not establish

  • NPSH required is an input from the pump curve. A different curve at the actual speed would change the margin.
  • The suction lift and friction are single values at the reported flow; a full system curve would show how the margin varies.
  • The model does not assess dissolved-gas effects, entrained air or suction-vessel geometry.
  • Cavitation damage and impeller wear require inspection; the calculation only establishes the hydraulic risk.