Infiltration Trench Calculator

Length and drain time of an infiltration trench from the stored runoff volume, void ratio and soil infiltration rate.

Geometry-based calculation.Storage-based sizing of a soakage trench with a Darcy drawdown estimate. No lateral spreading, no groundwater level and no native soil storage.

Workspace

Continue where you left off

Saved calculations in this browser can be reopened with their inputs intact.

Open Workspace

What this calculator does

An infiltration trench (French drain) manages a design storm by storing it in aggregate void space and releasing it into the soil. This calculator sizes the trench from the volume of runoff you must store and tells you how long that volume takes to drain away.

How to use it

  1. Enter the catchment area and the design rainfall for the storm you must handle.
  2. Set the runoff coefficient for the surface draining to the trench.
  3. Set the void ratio of the aggregate bed — 30 to 40 % is typical for washed stone.
  4. Enter the final infiltration rate from a test, and check the drain time against the interval between storms.

Governing formula

Governing Formula
V = A · P · C ; V_trench = V / n ; t = V / (k · A_base)

Where:

  • A = Catchment area [m²]
  • P = Design rainfall depth [m]
  • n = Void ratio of the aggregate [–]
  • k = Final infiltration rate [m/h]

Derived Equations:

Trench length for the chosen cross-section: L = V_trench / (w · d)

Worked example — 400 m² of paving with a 25 mm storm

The figures below were produced by running this page's own engine with the example inputs (Catchment area (m²), Design rainfall depth (mm), Runoff coefficient (–), Trench depth (m), Trench width (m), Aggregate void ratio (%), Final infiltration rate (mm/h)). If the calculator returns something different for the same numbers, that is a bug, not a rounding difference.

Expected results for the worked example
Required trench length38.1 m
Runoff to store8 m³
Drain time14000 h
AssessmentStore 8.0 m³ (drainage area 400 m² off 25 mm rain) → trench ≈ 38 m long at 0.6 × 1 m (35% voids). Drains in ≈ 14000 h at 25 mm/h.
  1. Runoff to store is 400 × 0.025 × 0.8 = 8 m³.
  2. At 35 % voids the trench must hold 22.9 m³ of aggregate bed.
  3. A 0.6 × 1.0 m trench therefore needs about 38 m, and drains the volume in roughly 22 hours.

Assumptions & limitations

Engineering calculation. Storage-based sizing of a soakage trench with a Darcy drawdown estimate. No lateral spreading, no groundwater level and no native soil storage.

  • Assumes the trench drains from the bottom only; a French drain distributed along the length drains faster.
  • No allowance for groundwater mounding, which can seriously reduce infiltration after repeated storms.
  • Infiltration rates reduce over time through clogging, so size with a factor of safety.

This tool supports professional engineering work; it does not replace a sealed design. Confirm every result against the applicable standard and a licensed engineer before it is built.

References & standards

  • Local stormwater infiltration practice notes.
  • BS EN 752-4 — underground drainage systems.
Engineering Disclaimer & Verification Notice

This calculator provides preliminary engineering estimates for informational and planning purposes. Actual reverse osmosis / engineering system performance depends on site conditions, feed-water chemistry, membrane characteristics, operating pressure, temperature, recovery limits, fouling/scaling potential, and system design. Verify results using project-specific data, manufacturer projections, and applicable engineering standards before final design or operation.