EngiMetric Arena / Engineering Trade-off

Choose a recovery rate that the plant can actually run

  • Engineering Trade-off
  • Water Treatment & Desalination
  • advanced

What you should take away: Evaluate a multi-constraint design decision against explicit limits and accept that a range of answers is correct, rather than searching for a single optimum.

The situation

A brackish-to-seawater RO plant is being set a design basis. The site has fixed two limits: the concentrate stream must stay below a stated salinity ceiling, and the electrical budget per cubic metre of permeate must not be exceeded. Within those limits, several recoveries are acceptable. Specify one.

Given

Scenario values with units
QuantityValueUnitNote
Feed flow 100 m³/h Design feed rate.
Feed TDS 35 000 mg/L Feed salinity. The rejected salt ends up in the concentrate.
Salt rejection 99.7 % Held constant across the range, which is optimistic at high recovery.
Feed pressure 55 bar Used by the energy engine for every candidate recovery.

Constraints

  • Membrane elements are supplied whole. A fraction of an element cannot be ordered.
  • Pressure vessels are loaded with a whole number of elements — 6 per vessel here.
  • Every vessel in the array is filled to the same element count.

Limits this decision must satisfy

Project limits the submitted value must satisfy
Limit Requirement If it is breached
Concentrate TDS ≤ 70000 mg/L Above the site ceiling the concentrate salinity limit is exceeded, which drives scaling risk and typically a recovery reduction.
Net specific energy with ERD ≤ 2.75 kWh/m³ Above the electrical budget the operating cost and the pump duty exceed what the project has approved.

More than one recovery or efficiency can satisfy every limit at once. There is no single right number here — find a value that holds all of them.

Your answer

Any value that satisfies every stated limit is a defensible answer.

What this challenge does not establish

  • Salt rejection is held at the stated 99.7 % across the whole range. Real rejection falls as recovery rises, so the concentrate figure is optimistic at the top of the band.
  • The energy engine uses a single feed pressure for every candidate; it does not re-derive pressure from the osmotic balance as recovery changes.
  • No scaling, fouling or boron/boride assessment is implied. Scaling risk in particular is what usually caps real recovery, and it is not modelled here.
  • Feed salinity is a single value, not a seasonal range.