EngiMetric Arena / Design Challenge

Specify a pump efficiency that keeps the duty inside its budget

  • Design Challenge
  • Mechanical & Fluid Engineering
  • intermediate

What you should take away: Separate a hydraulic requirement from an efficiency assumption, and see that every efficiency above a floor satisfies the same stated constraints.

The situation

A transfer pump must raise the liquid through a known static lift, pipe friction and fittings, and deliver a stated residual pressure at the discharge. The project caps the motor power at a stated figure. Pump and motor efficiencies are assumptions you choose. Specify the pump efficiency you would design to.

Given

Scenario values with units
QuantityValueUnitNote
Flow 60 m³/h Design flow.
Static lift 28 m Geometric rise. Fixed by the layout, not by the pump.
Pipe friction 12 m Friction loss in the pipework.
Minor losses 3 m Fittings and bends.
Residual pressure 4 bar Pressure required at the discharge.
Motor efficiency 95 % Assumed motor efficiency.
Approved motor power 18.5 kW The project power cap the duty must fit inside.

Constraints

  • Membrane elements are supplied whole. A fraction of an element cannot be ordered.
  • Pressure vessels are loaded with a whole number of elements — 6 per vessel here.
  • Every vessel in the array is filled to the same element count.

Limits this decision must satisfy

Project limits the submitted value must satisfy
Limit Requirement If it is breached
Motor power ≤ 18.5 kW Above the cap the motor duty exceeds what the project has approved for this duty, so the pump has to be oversized or the head re-examined.

More than one recovery or efficiency can satisfy every limit at once. There is no single right number here — find a value that holds all of them.

Your answer

Any value that satisfies every stated limit is a defensible answer.

What this challenge does not establish

  • No pump curve is modelled. This challenge does not consider the best-efficiency point, so it cannot tell you where a real pump should be selected.
  • Efficiencies are stated assumptions, not vendor data. A real selection needs manufacturer curves at the design flow.
  • Static lift, friction and minor losses are taken as fixed; none is re-evaluated as the design changes.
  • No allowance for suction-side conditions, NPSH, or start-up and shut-down transients.
  • Static friction and velocity head are not modelled separately from the stated losses.